Parameter Reference
D-148
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units WQ
View
Notes MBus
1501 AR Trip Mask.29 INTERNAL FAN FAIL
Same as PNO 1469
BOOL
TRUE
ALWAYS
TECHNICIAN
03529
1502 AR Trip Mask.30 CURRENT SENSOR
Setup::Motor Control::Auto Restart
Parameters::Motor Control::Auto Restart
BOOL
TRUE
ALWAYS
TECHNICIAN
03531
1503 AR Trip Mask.31 POWER LOSS STOP
Same as PNO 1502
BOOL
TRUE
ALWAYS
TECHNICIAN
03533
1505 AR Initial Delay
Same as PNO 1502
TIME
10.000
0.000 to 3600.000
s
ALWAYS
OPERATOR
03537
1506 AR Repeat Delay
Same as PNO 1502
TIME
60.000
0.000 to 3600.000
s
ALWAYS
OPERATOR
03539
1507 AR Active
Parameters::Motor Control::Auto Restart
BOOL
NEVER
OPERATOR
03541
1508 AR Restart Pending
Parameters::Motor Control::Auto Restart
BOOL
NEVER
OPERATOR
03543
1509 AR Restarts Remaining
Parameters::Motor Control::Auto Restart
USINT
0 to 20
NEVER
OPERATOR
03545
1510 AR Time Remaining
Parameters::Motor Control::Auto Restart
TIME
0.000 to 3600.000
s
NEVER
OPERATOR
03547
1511 Encoder Supply
Setup::Inputs and Outputs::Option
Parameters::Option IO::Encoder
USINT
(enum)
0
0:5 V
1:12 V
2:15 V
3:24 V
STOPPED
TECHNICIAN
03549
1512 Encoder Lines
Same as PNO 1511
DINT
2048
1 to 100000
STOPPED
TECHNICIAN
03551
1513 Encoder Invert
Same as PNO 1511
BOOL
FALSE
STOPPED
TECHNICIAN
03553
1514 Encoder Type
Same as PNO 1511
USINT
(enum)
0
0:QUADRATURE
1:CLOCK/DIRECTION
STOPPED
TECHNICIAN
03555
1515 Encoder Single Ended
Same as PNO 1511
BOOL
FALSE
STOPPED
TECHNICIAN
03557
1516 Encoder Speed
Monitor::Inputs and Outputs
Parameters::Option IO::Encoder
REAL
x.
Min to Max
RPM NEVER
OPERATOR
03559
1517 Encoder Count Reset
Same as PNO 1511
BOOL
FALSE
ALWAYS
TECHNICIAN
2
03561
1518 Encoder Count
Same as PNO 1516
DINT
-214783648 to 214783647
NEVER
TECHNICIAN
03563
1520 Actual Rotor T Const
Parameters::Motor Control::Tr Adaptation
REAL
x.
1 to 100000
ms
NEVER
ENGINEER
03567
1521 Tr Adaptation Output
Parameters::Motor Control::Tr Adaptation
REAL
x.
1 to 500
%
NEVER
ENGINEER
03569
1526 Energy Saving Lower Lim
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 100.00
%
ALWAYS
OPERATOR
03579
1527 Max Available Volts
Parameters::Motor Control::Tr Adaptation
REAL
x.
0 to 10000
V
NEVER
ENGINEER
03581
1528 Demanded Terminal Volts
Parameters::Motor Control::Tr Adaptation
REAL
x.
0 to 1000
V
NEVER
ENGINEER
03583
1529 Terminal Volts
Parameters::Motor Control::Tr Adaptation
REAL
x.
0 to 1000
V
NEVER
ENGINEER
03585
1533 Control Type
Setup::Motor Control::Control and Type
Parameters::Motor Control::Control Mode
USINT
(enum)
0
0:SENSORLESS
1:ENCODER FEEDBACK
STOPPED
TECHNICIAN
6
03593
1534 Clone Filename
Setup::Clone
Parameters::Device Manager::Clone
STRING[24]
clone
ALWAYS
TECHNICIAN
2
03595
1537 Clone Direction
Same as PNO 1534
USINT
(enum)
0
0:SAVE TO FILE
1:LOAD FROM FILE
ALWAYS
TECHNICIAN
2
03601
1538 Full Restore
Same as PNO 1534
USINT
(enum)
0
0:YES
1:PARTIAL
ALWAYS
TECHNICIAN
2
03603
1539 Application
Same as PNO 1534
USINT
(enum)
0
0:LOAD FROM FILE
1:LEAVE CURRENT APP
ALWAYS
TECHNICIAN
2
03605
1540 Other Parameters
Same as PNO 1534
USINT
(enum)
0
0:LOAD FROM FILE
1:LEAVE CURRENT VALUES
2:SET TO DEFAULT VALUES
ALWAYS
TECHNICIAN
2
03607
1541 Power Parameters
Same as PNO 1534
USINT
(enum)
0
Same as PNO 1540
ALWAYS
TECHNICIAN
2
03609
1542 Clone Start
Same as PNO 1534
BOOL
FALSE
ALWAYS
TECHNICIAN
2
03611
1543 Clone Status
Same as PNO 1534
USINT
(enum)
0:IDLE
1:SAVING
2:RESTORING
3:VERIFYING
4:DONE
5:CANNOT START
6:FAILED
7:NO SD CARD
8:VERIFY FAILED
9:FILE NOT OPENED
10:FILE INCOMPATIBLE
11:FILE FAILURE
12:POWER MISMATCH
13:APPLICATION FAILURE
14:PARAMETERS FAILURE
NEVER
TECHNICIAN
03613
1544 Filter Type
Parameters::Motor Control::Filter On Torque Dmd
USINT
(enum)
0
0:NONE
1:MAX ATTENUATION
2:MINIMUM PHASE
3:PHASE ADVANCE
4:NOTCH
ALWAYS
TECHNICIAN
03615
1545 Cut Off Frequency
Parameters::Motor Control::Filter On Torque Dmd
REAL
2000
20 to 6000
Hz
ALWAYS
TECHNICIAN
03617