D-149
Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units WQ
View
Notes MBus
1546 Frequency 1
Parameters::Motor Control::Filter On Torque Dmd
REAL
2000
20 to 6000
Hz
ALWAYS
TECHNICIAN
03619
1547 Frequency 2
Parameters::Motor Control::Filter On Torque Dmd
REAL
2000
20 to 6000
Hz
ALWAYS
TECHNICIAN
03621
1548 Factor
Parameters::Motor Control::Filter On Torque Dmd
REAL
0.20
0.10 to 1.00
ALWAYS
TECHNICIAN
03623
1549 Application Volts
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 150.00
%
ALWAYS
OPERATOR
03625
1550 Nameplate Mag Current
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
REAL
1.00
0.01 to 1000.00
A
STOPPED
TECHNICIAN
6
03627
1551 Product Code Flags
Parameters::Device Manager::Drive info
BYTE
NEVER
ENGINEER
03629
1554 Application Name
Parameters::Application::App Info
STRING[20]
NEVER
TECHNICIAN
03635
1560 Start Delay Enable
Parameters::Motor Control::Motor Sequencer
BOOL
FALSE
STOPPED
TECHNICIAN
03647
1565 Local Power Up Mode
Parameters::Motor Control::Sequencing
USINT
(enum)
0
0:AS WHEN POWERED DOWN
1:LOCAL
2:REMOTE
ALWAYS
TECHNICIAN
03657
1567 Modbus Mapping
Setup::Communications::Base Modbus
Parameters::Base Comms::Modbus
ARRAY[0..15]
ALWAYS
ENGINEER
03661
1568 Modbus Mapping[0]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03663
1569 Modbus Mapping[1]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03665
1570 Modbus Mapping[2]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03667
1571 Modbus Mapping[3]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03669
1572 Modbus Mapping[4]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03671
1573 Modbus Mapping[5]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03673
1574 Modbus Mapping[6]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03675
1575 Modbus Mapping[7]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03677
1576 Modbus Mapping[8]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03679
1577 Modbus Mapping[9]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03681
1578 Modbus Mapping[10]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03683
1579 Modbus Mapping[11]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03685
1580 Modbus Mapping[12]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03687
1581 Modbus Mapping[13]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03689
1582 Modbus Mapping[14]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03691
1583 Modbus Mapping[15]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03693
1632 Mapping Valid
Monitor::Communications::Base Modbus
Parameters::Base Comms::Modbus
BOOL
NEVER
OPERATOR
03791
1633 Application User Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 25.00
%
ALWAYS
OPERATOR
03793
1634 Start Delay
Parameters::Motor Control::Motor Sequencer
TIME
0.000
0.000 to 30.000
s
STOPPED
TECHNICIAN
03795
1635 Delay To Start
Parameters::Motor Control::Motor Sequencer
TIME
0.000 to Max
s
NEVER
TECHNICIAN
03797
1636 Manufacturing Flags
Parameters::Device Manager::Drive info
WORD
NEVER
ENGINEER
03799
1637 Engineer Password
Parameters::Keypad::Graphical Keypad
WORD
0000
ALWAYS
TECHNICIAN
03801
1640 Modbus Password
Setup::Communications::Option
Parameters::Option Comms::Modbus RTU
WORD
0000
ALWAYS
TECHNICIAN
03807
1641 VDC Lim Enable
Parameters::Motor Control::DC Link Volts Limit
BOOL
FALSE
STOPPED
TECHNICIAN
03809
1642 VDC Lim Level
Parameters::Motor Control::DC Link Volts Limit
REAL
91.0
78.0 to 100.0
%
STOPPED
TECHNICIAN
03811
1643 VDC Lim Active
Parameters::Motor Control::DC Link Volts Limit
BOOL
NEVER
TECHNICIAN
03813
1644 VDC Lim Output
Parameters::Motor Control::DC Link Volts Limit
REAL
x.x
Min to Max
Hz
NEVER
ENGINEER
03815
1645 Pwrl Enable
Parameters::Motor Control::Power Loss Ride Thru
BOOL
FALSE
STOPPED
TECHNICIAN
03817
1646 Pwrl Trip Threshold
Parameters::Motor Control::Power Loss Ride Thru
REAL
52.0
20.0 to 60.0
%
STOPPED
TECHNICIAN
03819
1647 Pwrl Control Band
Parameters::Motor Control::Power Loss Ride Thru
REAL
2.0
0.0 to 20.0
%
STOPPED
TECHNICIAN
03821
1648 Pwrl Accel Rate
Parameters::Motor Control::Power Loss Ride Thru
REAL
100
1 to 500
Hz/s STOPPED
TECHNICIAN
03823
1649 Pwrl Decel Rate
Parameters::Motor Control::Power Loss Ride Thru
REAL
100
1 to 500
Hz/s STOPPED
TECHNICIAN
03825
1650 Pwrl Time Limit
Parameters::Motor Control::Power Loss Ride Thru
TIME
30.000
0.000 to 300.000
s
STOPPED
TECHNICIAN
03827
1651 Pwrl Active
Parameters::Motor Control::Power Loss Ride Thru
BOOL
NEVER
TECHNICIAN
03829
1658 Current Diff Level
Parameters::Trips::Current Sensor Trip
REAL
25.00
0.00 to 100.00
%
ALWAYS
OPERATOR
03843
1659 Modbus TCP Password
Setup::Communications::Base Modbus
Parameters::Base Comms::Modbus
WORD
0000
ALWAYS
TECHNICIAN
03845
1900
Selected Application
USINT (enum) 0
0:BASIC SPEED CONTROL
1:AUTO/MANUAL
CONTROL
2:SPEED RAISE / LOWER
3:SPEED PRESETS
4:PROCESS PID
ALWAYS TECHNICIAN 5
04327
1901
RL Ramp Time
Setup::Application::Raise Lower
TIME
10.0
0.0 to 600.0
s
ALWAYS TECHNICIAN 5,8
04329
1902
RL Reset Value
Setup::Application::Raise Lower
REAL
0.0
-500.0 to 500.0
%
ALWAYS TECHNICIAN 5,8
04331
1903
RL Maximum Value
Setup::Application::Raise Lower
REAL
100.0
-500.0 to 500.0
%
ALWAYS TECHNICIAN 5,8
04333
1904
RL Minimum Value
Setup::Application::Raise Lower
REAL
-100.0
-500.0 to 500.0
%
ALWAYS TECHNICIAN 5,8
04335