![background image](http://html1.mh-extra.com/html/omron/nt-series-support-tool-for-windows-v4/nt-series-support-tool-for-windows-v4_operation-manual_744237488.webp)
Appendix A
Data Conversion
472
Correction related to history screens
When a history screen is converted, an error message may be displayed due to
differences in the handling of the screen numbers of the frequency history screen
and the occurrence history screen between conventional and new models.
Difference:
New models:
Screen No. 9001 and No. 9002
History screens (occurrence order, frequency order)
cannot be edited.
Conventional models: Screen No. 1997 and No. 1998
History screens (occurrence order, frequency order)
can be edited.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a conventional
model, a history
screen (occurrence
order, frequency or-
der) is edited.
With a new model,
the history screen is
deleted (displaying
the edited history
screen is possible
by specifying it from
a PT).
The screen no. xxx
was a history occur-
rence (frequency)
screen that is not
supported in this
model. It is dis-
carded.
––
Correction related to the number of memory tables
Since the number of entries that can be used in the memory tables depend on the
PT model, conversion is executed in the manner shown below.
Difference
NT11S/
NT11
NT20/
NT20S
NT600S
NT30
NT30C
NT620S
NT620C
NT625C
NT21
NT31
NT31C
NT631
NT631C
Numeral
memory table
128
128
512
512, or
1000
512, or
1000
512,
1000, or
2000
Character
string memory
table (String
table)
128
128
256
256, or
1000
256, or
1000
256,
1000, or
2000
Bit memory
table
––
––
––
256
256
256, or
1000
Extended I/O
input table
––
––
––
64
––
––
Extended I/O
output table
––
––
––
64
––
––
F-key input
notify table
4
––
––
––
––
––
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
A memory table
number that is out-
side the allowable
range for the
memory table is
used for display or
input.
The memory table
number is reset to
0.
[Object Name] re-
fers to invalid nu-
meral table entry.
The referenced
table entry is reset
to entry 0.
Correct the memory
table number to the one
that is in the valid range.
If the memory table
number is specified in a
program, correct it also.
(Refer to
Dialog Box
Settings in the PT Con-
figuration
on page 46.)
Summary of Contents for NT-SERIES - SUPPORT TOOL FOR WINDOWS V4
Page 1: ...Cat No V061 E1 06 Support Tool for Windows Ver 4 NT Series OPERATION MANUAL...
Page 2: ......
Page 3: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised July 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 14: ......
Page 80: ......
Page 94: ......
Page 338: ......
Page 422: ......
Page 458: ......
Page 478: ......
Page 502: ......
Page 508: ......
Page 532: ......
Page 556: ......
Page 560: ......
Page 562: ......
Page 564: ......
Page 570: ......
Page 572: ......
Page 584: ......
Page 590: ......
Page 592: ......
Page 593: ......