6-1
Section
Common Operation
137
responding object will be enabled/disabled according to the interlock bit: when
the PLC Address set on the Interlock address is ‘ON’ the touch switch/thumb-
wheel/numeral input/string input will work; if the address is ‘OFF’, the touch
switch/thumbwheel/numeral input/string input will not respond to the touches.
The interlock functionality is supported for the PT models NT21 and
NT31/631-V2 and above. The temporary input object does not support interlock
function.
Operation procedure
Select the Interlock tab on the property sheet of the screen object that supports
Interlock.
Property setting
This property page will be the same for all other supported objects. Only the cap-
tion will be changed according to the object.
Interlock Check Box
To ON/OFF interlock. By default it is OFF.
PLC Bit Address
To specify the bit address associated with Interlock. Interlock is ON, if this bit is
set, OFF otherwise.
IO Comment
I/O Comment for the address specified.
Conversion
For conversions due to cut/copy/paste, drag/drop of screen elements with inter-
lock settings (e.g. Touch Switch, Thumbwheel, Numeral Input, and String Input)
Summary of Contents for NT-SERIES - SUPPORT TOOL FOR WINDOWS V4
Page 1: ...Cat No V061 E1 06 Support Tool for Windows Ver 4 NT Series OPERATION MANUAL...
Page 2: ......
Page 3: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised July 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 14: ......
Page 80: ......
Page 94: ......
Page 338: ......
Page 422: ......
Page 458: ......
Page 478: ......
Page 502: ......
Page 508: ......
Page 532: ......
Page 556: ......
Page 560: ......
Page 562: ......
Page 564: ......
Page 570: ......
Page 572: ......
Page 584: ......
Page 590: ......
Page 592: ......
Page 593: ......