WARNING:
Do not remove the J3-ENC or J4-ENC encoder cable connectors
that are located near the end of arm break-away sensor connector. If they are
removed, the calibration data will be lost and the robot must be factory recal-
ibrated which requires special software and tools.
This is typically used with a break-away sensor at the end of arm tooling to immediately turn
OFF high power when the circuit becomes open. The end of arm break-away sensor connector
location and pin details are provided below.
Additional Information
: Refer to End of Arm Break-away Sensor on page 26 and
Technical Specifications on page 131 for more information.
IMPORTANT:
When connecting a cable to the End of Arm Break-away Sensor
Connector, be careful to not dislodge or remove the encoder connectors nearby.
Figure 1-12. End of Arm Break-away Sensor Connector Location
Table 1-5. End-effector Break-away Connector Pin Details
Pin #
Description
Pin Location
1
Input
2
+24 VDC Supply