Chapter 6: System Operation
Automatic Mode
Automatic mode is used when the robot is operating under normal conditions.
When the robot is placed in Automatic mode, program execution will control the robot up to
the robot's maximum speed.
!
DANGER: PERSONAL INJURY RISK
The robot can move unexpectedly in Automatic mode. Ensure that personnel
stay clear of the robot work area.
To place the robot in Automatic mode, use the Front Panel keyswitch and rotate it to the right
position (
).
Operation Mode
Operation mode should be used when the robot is operating under normal conditions and is
being controlled by the NJ-series Robot Integrated CPU Unit with EtherCAT communications.
To place the robot in operation mode, set the OP/SV two-position dip switch on the robot inter-
face panel to the OP position (left) as shown in the figure below.
IMPORTANT:
The position of the dip switch is checked during power-up only.
Changing this switch position while 24 VDC power is supplied will not change
the mode of the robot until power is cycled. It is recommended to remove all
robot power before changing the position of this switch.
Figure 6-5. Operation Mode Selected
Service Mode
Service mode is used for special conditions when the robot must be accessed with methods
other than EtherCAT communications.
NOTE:
If the robot is placed in service mode, it will not communicate with an
NJ-series Robot Integrated CPU Unit.
IMPORTANT:
The operating mode switch state is checked only during robot
startup after power is applied.
If the following conditions are present on your system, contact your local OMRON rep-
resentative for support.
24402-000 Rev B
eCobra 600 and 800 Robots with EtherCAT
105