5 - 13
5 Communications Data for Modbus
E5
C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
5
-1 V
ariab
le A
re
a (Setting
Rang
e) List
5
Address
Parameter name
Setting (monitor) value
Level
Four-byte
mode
Two-byte
mode
1100
3100
Protocol Setting (See
note.)
*1
H'00000000 (0): CompoWay/F
H'00000001 (1): Modbus
H'00000002 (2): CMP
H'00000003 (3): FINS
H'00000004 (4): MCP4
Communicat
ions setting
1102
3101
Communications Unit No.
H'00000000 to H'00000063 (0 to 99)
1104
3102
Communications Baud
Rate
*1
H'00000003 (3): 9.6
H'00000004 (4): 19.2
H'00000005 (5): 38.4
H'00000006 (6): 57.6
1106
3103
Communications Data
Length
*1
H'00000007 (7): 7
H'00000008 (8): 8
1108
3104
Communications Stop
Bits
*1
H'00000001 (1): 1
H'00000002 (2): 2
110A
3105
Communications Parity
*1
H'00000000 (0): None
H'00000001 (1): Even
H'00000002 (2): Odd
110C
3106
Send Data Wait Time
*1
H'00000000 to H'00000063 (0 to 99)
*1
After communications parameters have been changed, reset the Digital Controller to enable them.