3 Communications Data for CompoWay/F
E5
C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
3-1 V
ariab
le A
rea (Setting
Ran
g
e) List
3
C5 (85)
0060
PID 7 Proportional
Band
H'00000001 to H'0000270F (0.1 to 999.9)
PID Setting
to
to
C5 (85)
006C
PID 7 Manual Reset
Value
H'00000000 to H'0000270F (0 to 9999)
C5 (85)
0070
PID 8 Proportional
Band
H'00000001 to H'0000270F (0.1 to 999.9)
to
to
C5 (85)
007C
PID 8 Manual Reset
Value
H'00000000 to H'0000270F (0 to 9999)
C9 (89)
0000
Upload Setting 1
H'00000000 to H'000000B3 (0 to 179)
Communications
setting
C9 (89)
0001
Upload Setting 2
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0002
Upload Setting 3
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0003
Upload Setting 4
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0004
Upload Setting 5
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0005
Upload Setting 6
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0006
Upload Setting 7
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0007
Upload Setting 8
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0008
Upload Setting 9
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0009
Upload Setting 10
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000A
Upload Setting 11
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000B
Upload Setting 12
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000C
Upload Setting 13
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000D
Upload Setting 14
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000E
Upload Setting 15
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
000F
Upload Setting 16
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0010
Upload Setting 17
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0011
Upload Setting 18
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0012
Upload Setting 19
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0013
Upload Setting 20
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0014
Upload Setting 21
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0015
Upload Setting 22
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0016
Upload Setting 23
H'00000000 to H'000000B3 (0 to 179)
C9 (89)
0017
Download Setting 1
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0018
Download Setting 2
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0019
Download Setting 3
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001A
Download Setting 4
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001B
Download Setting 5
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001C
Download Setting 6
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001D
Download Setting 7
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001E
Download Setting 8
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
001F
Download Setting 9
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0020
Download Setting 10
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0021
Download Setting 11
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0022
Download Setting 12
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0023
Download Setting 13
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0024
Download Setting 14
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0025
Download Setting 15
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0026
Download Setting 16
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0027
Download Setting 17
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0028
Download Setting 18
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
0029
Download Setting 19
H'0000001E to H'000000B3 (30 to 179)
C9 (89)
002A
Download Setting 20
H'0000001E to H'000000B3 (30 to 179)
Variable
type
Address
Parameter name
Setting (monitor) value