6 Programless Communications
6 - 16
E5
C-T Digital Temperature Controllers Programmable Type Communications Manual (H186)
(5)
copy
and execute the copy operation.
If you select
all
, the parameters settings will be copied to all of the slaves. If you select a
number, the parameters settings will be copied to the slave with the selected
communications unit number.
Note: 1 You cannot cancel copying once the copying operation has been started. Even if you change the set value
during the copying operation, the current processing will be continued.
2 If copying fails, the copying operation will be aborted and the parameter settings will not be copied to the
remaining slaves.
3 The following parameters are not copied.
•
Auto/Manual
•
RUN/RESET
•
SP Mode
•
Hold
•
Manual MV
For a Mitsubishi PLC, the ERR. indicator on the Serial Communications Module will light during the
copying process, but this does not indicate an error. The ERR. indicator will go out when the PLC is
restarted.
Refer to
for specific copying procedures.
Set value
Description
off
(
e0
**)
Copying is not in progress. The display will automatically return to
off
when the
copy operation is completed normally.
If the copy operation fails,
E
** will be displayed instead of
off
. The asterisks will
be replaced with the communications unit number of the slave where copying
failed.
Example: If copying failed at the slave with communications unit number 2,
e002
will be displayed.
all
The parameter settings are copied to the slaves starting with the slave with
communications unit number 1 and continuing on to the slave with the
communications unit number that is set in the Highest Communications Unit No.
parameter. When copying is started, the PV display on the slave will change to
copy
. The copying operation is completed when all of the slaves are reset.
1 to 31
The parameter settings are copied to the slave with the specified communications
unit number, and then all of the slaves are automatically reset.