I/O Connector Wiring Procedure
Use the following procedure to wire the I/O connector.
1
Ensure the I/O connector is not connected to the IPC.
2
Remove the sheath from the wires.
7 mm
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Remove the I/O connector from the IPC.
4
Insert a screwdriver in the small groove above the cable entry
1
to unlock the cable entry and
then push the wire all the way to the back of the cable opening
2
.
1
2
5
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5 Installation
5-33
IPC Application Controller User's Manual (I632)
5-4
W
ire
5
5-4-4
Wire the I/O Connector
Summary of Contents for AC1-152000
Page 1: ...IPC Application Controller User s Manual I632 E 03...
Page 4: ...Introduction 2 IPC Application Controller User s Manual I632...
Page 32: ...Revision History 30 IPC Application Controller User s Manual I632...
Page 38: ...1 Overview 1 6 IPC Application Controller User s Manual I632...
Page 62: ...2 Hardware 2 24 IPC Application Controller User s Manual I632...
Page 86: ...3 Software 3 24 IPC Application Controller User s Manual I632...
Page 162: ...5 Installation 5 50 IPC Application Controller User s Manual I632...
Page 174: ...6 Operating Procedures 6 12 IPC Application Controller User s Manual I632...
Page 216: ...7 Maintenance 7 42 IPC Application Controller User s Manual I632...
Page 227: ...I Index I 1 IPC Application Controller User s Manual I632 I...