Power Connector Wiring Procedure
Use the following procedure to wire the power connector.
1
Ensure the power connector is not connected to the IPC.
2
Remove the sheath from the power supply wires.
7 mm
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Insert a screwdriver in the small opening above the cable opening
1
to unlock the cable entry
and then push the wire all the way to the back of the cable opening
2
.
2
1
1
2
Pin
Description
1
24 VDC
2
0 VDC
4
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5 Installation
5-30
IPC Application Controller User's Manual (I632)
Summary of Contents for AC1-152000
Page 1: ...IPC Application Controller User s Manual I632 E 03...
Page 4: ...Introduction 2 IPC Application Controller User s Manual I632...
Page 32: ...Revision History 30 IPC Application Controller User s Manual I632...
Page 38: ...1 Overview 1 6 IPC Application Controller User s Manual I632...
Page 62: ...2 Hardware 2 24 IPC Application Controller User s Manual I632...
Page 86: ...3 Software 3 24 IPC Application Controller User s Manual I632...
Page 162: ...5 Installation 5 50 IPC Application Controller User s Manual I632...
Page 174: ...6 Operating Procedures 6 12 IPC Application Controller User s Manual I632...
Page 216: ...7 Maintenance 7 42 IPC Application Controller User s Manual I632...
Page 227: ...I Index I 1 IPC Application Controller User s Manual I632 I...