2 Starting a Sample System
EtherCAT Communication Unit USER’S MANUAL (3G3AX-MX2-ECT)
2-7 Co
mm
un
icatio
n Star
ting a
nd Op
eration
Chec
king
with C
J1W
-NCx82 Mas
ter
2
2-7-4 C
hec
king the
In
v
er
ter
and EtherCA
T Comm
unication
Unit
Check the POWER indicator and other indications of the inverter to confirm that power is being supplied
to the inverter.
Check the status indicators of the EtherCAT Communication Unit to see that the status has changed to
normal operation from initial processing.
1st unit
2nd unit
*
If three or more units are connected, the status LEDs behave in the same way as the LEDs on the first unit,
except for the last unit.
L/A OUT on the last unit is always unlit.
Execute the PLC control program and check that the operation is normal.
2-7-4
Checking the Inverter and EtherCAT Communication Unit
L/A IN
L/A OUT
RUN
ERR
Initial processing
ON
ON
OFF
OFF
Normal operation
Flashing
Flashing
ON
OFF
L/A IN
L/A OUT
RUN
ERR
Initial processing
ON
OFF
OFF
OFF
Normal operation
Flashing
OFF
ON
OFF
2-7-5
Checking the Operation
Summary of Contents for 3G3AX-MX2-ECT
Page 23: ...20 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT CONTENTS ...
Page 31: ...1 EtherCAT Network 1 8 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 85: ...4 Inverter Control 4 18 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 111: ...5 CiA402 Drive Profile 5 26 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 162: ...Index 1 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT I Index ...
Page 164: ......