Appendices
A-28
EtherCAT Communication Unit USER’S MANUAL (3G3AX-MX2-ECT)
3014
hex
75
hex
144C
hex
Communication
Station No. Selection
C072
RW
1 to 247
Possible
(TxPDO)
3014
hex
77
hex
144E
hex
Communication Parity
Selection
C074
RW
00: Disabled
01: Even
02: Odd
Possible
(TxPDO)
3014
hex
78
hex
144F hex
Communication Stop
Bit Selection
C075
RW
1: 1 bit
2: 2 bits
Possible
(TxPDO)
3014
hex
79
hex
1450 hex
Operation Selection on
Communication Error
C076
RW
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free-run stop
04: Deceleration stop
Possible
(TxPDO)
3014
hex
7A
hex
1451 hex
Communication Error
Timeout Period
C077
RW
0: Timeout disabled
1 to 9999
0.01 [s]
Possible
(TxPDO)
3014
hex
7B
hex
1452 hex
Communication Wait
Time
C078
RW
0 to 1000
1 [ms]
Possible
(TxPDO)
3014
hex
7E
hex
1455 hex
FV Adjustment
C081
RW
0 to 2000
0.1 [%]
Possible
3014
hex
7F
hex
1456 hex
FI Adjustment
C082
RW
0 to 2000
0.1 [%]
Possible
3014
hex
82
hex
1459 hex
Thermistor Adjustment
C085
RW
0 to 2000
0.1 [%]
Possible
3014
hex
88
hex
145F hex
Debug Mode Selection
C091
RW
For factory adjustment (Do not change.)
Possible
3014
hex
8D
hex
1464 hex
Communication
Selection
C096
RW
00: Modbus communication
(Modbus-RTU)
01: Communication between
inverters
02: Communication between
inverters (management)
Possible
(TxPDO)
3014
hex
8F
hex
1466 hex
Co-inverter
Communication
Starting Station
Number
C098
RW
1 to 8
Possible
(TxPDO)
3014
hex
90
hex
1467 hex
Co-inverter
Communication
Ending Station
Number
C099
RW
1 to 8
Possible
(TxPDO)
3014
hex
91
hex
1468 hex
Co-inverter
Communication
Starting Selection
C100
RW
00: 485 terminals start
01: Always started
Possible
(TxPDO)
3014
hex
92
hex
1469 hex
UP/DWN Storage
Selection
C101
RW
00: Do not store frequency data
01: Store frequency data
Possible
(TxPDO)
3014
hex
93
hex
146A
hex
Reset selection
C102
RW
00: Trip reset at power-ON
01: Trip reset at power-OFF
02: Enabled only during trip (Reset
when the power is ON.)
03: Trip reset only
Possible
3014
hex
94
hex
146B
hex
Reset Restart Selection
C103
RW
00: 0 Hz restart
01: Frequency matching restart
02: Frequency pull-in restart
Possible
(TxPDO)
3014
hex
95
hex
146C
hex
UP/DWN Clear
Terminal Mode
C104
RW
00: 0 Hz
01: EEPROM data at power ON
Possible
(TxPDO)
3014
hex
96
hex
146D
hex
MP Gain Setting
C105
RW
50 to 200
1 [%]
Possible
3014
hex
97
hex
146E
hex
AM Gain Setting
C106
RW
50 to 200
1 [%]
Possible
3014
hex
9A
hex
1471 hex
AM Bias Setting
C109
RW
0 to 100
1 [%]
Possible
3014
hex
9C
hex
1473 hex
Overload 1 Warning
Signal Level 2
C111
RW
0 to 20000
0.01 [%]
Possible
3014
hex
AF
hex
1486 hex
Output P1/EDM ON
Delay Time
C130
RW
0 to 1000
0.1 [s]
Possible
(TxPDO)
3014
hex
B0
hex
1487 hex
Output P1/EDM OFF
Delay Time
C131
RW
0 to 1000
0.1 [s]
Possible
(TxPDO)
3014
hex
B1
hex
1488 hex
Output P2 ON Delay
Time
C132
RW
0 to 1000
0.1 [s]
Possible
(TxPDO)
3014
hex
B2
hex
1489 hex
Output P2 OFF Delay
Time
C133
RW
0 to 1000
0.1 [s]
Possible
(TxPDO)
Index
Sub-
index
Register
No.
Function name
Parameter
No.
R/W
Monitor and setting items
Data
resolution
PDO
map
Summary of Contents for 3G3AX-MX2-ECT
Page 23: ...20 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT CONTENTS ...
Page 31: ...1 EtherCAT Network 1 8 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 85: ...4 Inverter Control 4 18 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 111: ...5 CiA402 Drive Profile 5 26 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Page 162: ...Index 1 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT I Index ...
Page 164: ......