– 45 –
CHAPTER 4
OFFICE DATA DESIGN
2.1 System Data Assignment
ACD system basic data is as follows. For details of system data, refer to Data Programming Sheets.
Basic ACD data
STEP 1: ASYD - SYS1, INDEX2:
01 Hex (ACDP is mounted)*
INDEX31:
04 Hex*
INDEX70, b6:
1 (Announcement Trunks used for delay announcements/night
announcements is provided)
INDEX61, b5:
0 (UCD Call Waiting Display is out)
Note:
UCD Call Waiting
Display service cannot be used for ACD System.
INDEX79, b6:
0 (ACD/OAI in service)*
INDEX80, b3:
0 (Static ACD messages (Break, Ready, etc.) is displayed on
the top line of the LCD)
INDEX89, b3:
0/1 (CPU ACT/STBY changeover is not in service/in service)*
INDEX207, b0:
1 (ACDP SYS0 is mounted)
Note 1
*
INDEX207, b1:
0/1 (ACDP SYS1 is not mounted/mounted)
Note 1
*
Note 1:
b0=1, b1=0 for Single ACDP system/b0=1, b1=1 for Dual ACDP system.
INDEX241, b2:
1 (Call Processing Event Notification)*
INDEX241, b3:
1 (Details of SCF Error Notification)
INDEX448, b1:
1 (ACDP specifications UP)
STEP 2: ASYDL - SYS1, INDEX513:
01 Hex (LDM usage)*
INDEX515~518: IP address (Hex) for Telephony Server over External LAN
Note 5
*
INDEX519~522: Subnet Mask (Hex) for Telephony Server over External LAN
Note 5
*
INDEX523~526: Default Gateway Address for External LAN
Note 5
*
Gateway Address (IP Address of Router) of Network connect-
ing Telephony Server
INDEX864, b0: =1 (Built-in IP, ACDP is used)* (When Built-in IP/ACDP is
used, Index 864, b4 must be assigned as data “1”, and Index
864, b5 must be assigned as “0.”)
INDEX864, b1: Output the system message when TCP-IP connection is normal-
ly disconnected*
0/1=Effective/Ineffective
INDEX864, b4: Assign number of ports of Status Monitoring for terminal
(SMFN).
0/1=2 ports/8 ports (Normal Setting)
Note 2 Note 3
INDEX864, b5: Clear SMFN when the FCCS Link is down.
0/1=Clear (Normal Setting)/Not Clear
Note 2 Note 4
INDEX867, b3: (
For countries except North America
) Improvement of SCF6
Request for Monitor Connection.
0/1 = Out of service/In service
Note 2:
This identical data value must be assigned to all nodes.
Note 3:
When “Status Monitor Facility Request (SMFR), FN=126” is used, always assign 0 (2 ports).
Note 4:
Although this data is valid only when INDEX864 b4=1 (8 ports), this bit must be assigned as data “0” when
INDEX864 b4=0 (2 ports).
Note 5:
This data is assigned by ADTM. The assigned ADTM data is automatically written into the System Data.
Summary of Contents for SV8500
Page 1: ...FP85 104 S1 Data Programming Manual ACD NWA 041687 001 ISSUE 1 0...
Page 12: ...PL 6 This page is for your notes...
Page 130: ...114 A 31A ABANDONED CALL SEARCH ACD PROGRAMMING None...
Page 364: ...348 CHAPTER 6 This page is for your notes...
Page 409: ...Printed in Japan 0807 010...
Page 410: ......