30 | ni.com | NI EDIDS-2400 Series User Manual
If the green and amber LEDs directly under the controller Ethernet port are not active or blinking, then there
is no physical connection to a network router or PC, or there is no power to the controller. Please diagnose
the Ethernet cable connection or controller power problem.
If none of the above suggestions resolve the system connection problem, follow the
instructions below to reset the system controller network interface settings to DHCP.
cRIO-9082 Controller
To manually reset the network settings of the cRIO-9082 controller included with 3-, 6-, 9-, and 12-channel DI Driver
Systems, follow the steps below:
1. Power up the cRIO-9082 controller.
2. Switch the
IP RESET
switch to
ON
.
3. Press and immediately release the
reset
button. This will cause the controller to reboot normally and start the DI
Driver System software. However, the network settings will be reset to DHCP mode. Wait about 1 minute for both the
USER1 and USER FPGA1 LEDs to start blinking.
4. Switch the
IP RESET
switch to
OFF
.
Note:
NI does not recommend leaving DHCP mode for the DI Driver System controller because the IP address
may change each time the system is powered. Each time the IP address changes, the
Search for SCM Target...
dialog must be opened within the SCM console to locate the system on the network. If the system controller network
interface is in DHCP mode, and the controller is not connected to a DHCP router, the controller will default to a link-
local IP address of 169.254.X.X. If this happens, a connection with the system can still be established via direct,
"point-to-point" if the Windows PC LAN IP address is configured to a similar IP address, but different in the last
address number. If the system controller is allowed to default to the link-local address, follow the instructions above
for
Use SCM "Backup Target" Feature to Discover the IP Address
to identify the exact link-local IP address.
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...