Tip Strip: Raw voltage input
Units: V
Detail: Raw voltage signal sensed by the NI 9220 module.
AIX_Conv
Tip Strip: Calibration table
Detail: 1D Lookup table for converting the analog input to engineering units. It is assumed that the conversion
is linear and the table is 2x2. The X values correspond to the
(V) while the Y values correspond to the
engineering parameter
(u), such as Rail Pressure (bar).
AIX
Tip Strip: Output from calibration table
Units: Same as
Detail: Engineering parameter such as Rail Pressure (bar) which is interpolated by the
1D Table. The unit
(u) indicates the units specified in
Enable_AIX_Filt
Tip Strip: Enable use of filter
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...