Tip Strip: Threshold for decremental throttle motor negative voltage after the throttle plate stops moving. (Negative)
Units: V
Detail: Indicates a threshold for decremental throttle motor negative voltage after the throttle plate stops moving.
When this decremental threshold is reached, the drive stops and transitions to the post calibration phase. This
parameter should be a negative value.
PsnCalOffset_ChX
Tip Strip: The amount that the signal must change before the motor voltage increment/decrement reaches the
specified threshold, terminating the calibration process for that direction. (Positive)
Units: V
Detail: The position calibration process tracks the primary position sensor signal as the throttle plate moves toward
the minimum and maximum positions. This offset is the amount that the signal must change before the motor
voltage increment/decrement reaches the specified threshold, terminating the calibration process for that direction.
Typically 0.005 V is adequate. If this parameter is 0, then the calibration process will push harder toward the
minimum/maximum positions. When this happens, the minimum and maximum positions can be difficult to achieve
during control, and cause the final output to the throttle motor to exceed the limit. This parameter should be a
positive value.
PsnCalDiff_Thresh_ChX
Tip Strip: Minimum threshold for the expected range of throttle plate travel. (Positive)
Units: V
Detail: At the completion of the position calibration process, the absolute value of the difference between the
maximum and minimum position sensor signal voltages is compared against this threshold. If it is less than the
threshold, then there was something wrong with the position calibration process because the throttle plate did not
move through the expected range of travel, or the position sensor is faulty. This fault is indicated by the Pos Cal Diff
Fault Boolean indicator within the Position Cal Out cluster.
Analog
X
Range_Ch
Y
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...