NI EDIDS-2400 Series User Manual | © National Instruments | 37
specified IP address. If the controller at the specified IP address is valid, then the
Begin Update
button at the bottom
will be enabled.
6. Two options are available for selection before beginning the update process.
a.
Backup target before update
: This option may be selected if it is desired to create a backup image of
the system controller before updating the software to the latest version. If selected, a Zip file save dialog will
open to select the path and name of the backup zip file to be saved.
b.
Preserve calibration files
: This option may be selected if it is desired to preserve the current calibration
files on the system controller. Otherwise the current calibration files on the system controller will be
overwritten during the software update process.
7. Press the "Begin Update" button at the bottom to start the software update process. The process will take about
5 to 10 minutes. During the update process, the cursor will show as busy while hovered over the dialog. When the
process completes, a beep sound will be generated and the controller will be rebooted. Wait for the
USER1
and
USER FPGA1
LEDs to start blinking and then use the
Search for Target...
feature of SCM to reconnect to the
controller and download the new user interface files from the controller. It is important to check the
Download Files
check box within the
Search for Target...
dialog in order to have the user interface files compatible with the updated
system software.
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...