RailP_Max_Thresh
Tip Strip: Rail pressure maximum threshold which causes a critical fault and shuts down associated PFI LSX
channels
Units: bar
Detail: An upper threshold for rail pressure which defines a critical fault level that could potentially damage the fuel
system. If this threshold is exceeded, the low-side channels controlling the IMV and HPV turn off until the
error has been cleared.
RailP_Fault
Tip Strip: Indicates the rail pressure fault status
Detail: Indicates that the rail pressure has exceeded the value specified in
. This fault must be
.
BattV
Tip Strip: Battery voltage measured by the DI Driver module
Units: V
Detail: Battery voltage measured by the DI Driver module. Battery voltage is used to calculate, in real time, the
current supplied to the IMV and HPV solenoids, to ensure that the current does not exceed 3A.
RailP_Setpoint
Tip Strip: Rail pressure setpoint to PID controller
Units: bar
Detail: Desired rail pressure setpoint.
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...