NI EDIDS-2400 Series User Manual | © National Instruments | 81
Tip Strip: Enables PFI Driver module operation
Detail: If a PFI driver module is inserted in the
ON
, then
the controller begins communicating with the module and allows the module to operate.
PFI_Mode
Tip Strip: Selects operating mode for PFI Driver module
Detail: Operating mode applied to the PFI Driver module.
The PFI Driver module can be assigned a mode of operation which will apply to all PFI channels. The lowside
channels are not affected by this mode parameter. The
refers to the mode of sending injection commands
to the channels of the module.
Direct Mode:
The PFI Driver module PFI channels are commanded directly by external digital inputs of the NI 9411
modules. The digital input which commands each channel can be configured via the
window. The
digital input level which commands the PFI channel
ON
is configured via the
Invert
window. The duration of the injection command is determined by the direct duration of the digital input.
Calibration Mode:
Calibration mode is for the purpose doing injector flow calibrations. Calibration mode is
configured via the
window for a specified number of injection events, command duration
and command period. Only one PFI channel of the module may be enabled for Calibration Mode. If more than one
channel is enabled, then commands will not be delivered.
Triggered Multi-Pulse (TMP) Mode:
The PFI Driver module PFI channels are commanded by a specified sequence
of pulses and triggered by an external digital rising or falling edge to the assigned 9411 digital input channel. The
pulse sequence is configured via the
window. The external trigger channel is
assigned via the
Engine Position Tracking (EPT) Mode:
The PFI Driver module PFI channels are commanded by a specified
sequence of pulses and triggered by crankshaft angle events for each pulse, with respect to an assigned Top Dead
Center (TDC) reference value. The pulse sequence is configured via the
window. The TDC reference value is configured via the
tab of the
window. Engine position tracking parameters are configured via the
window for a variety of crank and cam signal patterns.
PFI_OneShot
Tip Strip: Generates one-shot command to selected channel
Detail: When pressed, the PFI Driver module will deliver a one-shot pulse to the PFI channel selected in
, having a duration specified by
This button returns to the
OFF
state
automatically.
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...