NI EDIDS-2400 Series User Manual | © National Instruments | 165
Tip Strip: Specifies the period length, in number of cycles, for the skip fire sequence in EPT Mode (Min = 1).
Detail: Specifies the number of cycles included in a skip fire sequence when the PFI injector is operated in EPT
mode. For example, if the number 7 is entered, the PFI injector will continuously repeat a seven cycle sequence as
long as
is enabled for the desired channel.
PFI1_SkipFire_OnCycle
Tip Strip: Specifies the number of active cycles during skip fire sequence in EPT Mode (Min = 1).
Detail: Specifies the number of active cycles included in a Skip Fire Sequence when the DI injector is operated
in EPT mode. For example, if the number 4 is entered and
is set to 7, the PFI injector
will continuously repeat a seven cycle sequence with four active cycles, followed by three inactive cycles as
long as
is enabled for the desired channel. It is also manipulated by the corresponding
control in all the
windows.
TMP Pulse Enable
Tip Strip: Enables injection pulse
Detail: When
ON
, the TMP Mode command to the PFI Driver module will be active for the specified duration. When
OFF
, the command will be inactive, but the specified timing and duration will still be implemented. Therefore, the
timing of the adjacent pulses will remain the same whether the pulse is
ON
or
OFF
Delay
Tip Strip: Time until beginning of this injection pulse
Units: msec
Detail: Specifies the delay of the start of injection from the trigger event.
Duration Ch1
Tip Strip: Duration of injection pulse
Units: msec
Detail: Time duration of the TMP Mode injection pulse. The
ON/OFF
button above each
and
parameter determines whether the pulse will be active or inactive.
Duration Ch2-4
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...