Detail: Indicates the initial drive voltage to the throttle motor for negative position calibration. This voltage should be
selected to move the throttle plate most of the way toward minimum position without hitting minimum position. This
parameter should be a negative value.
uPsnCalInc_ChX
Tip Strip: Incremental drive voltage applied to the throttle motor to keep the throttle plate moving toward the
maximum position. (Positive)
Units: V
Detail: Indicates the incremental drive voltage to the throttle motor to keep the throttle plate moving toward
maximum position. This incremental value is applied as necessary after the throttle plate stops moving due to the
uPsnCalPos_Init_ChX
voltage. This parameter should be a positive value.
uPsnCalDec_ChX
Tip Strip: Decremental drive voltage applied to the throttle motor to keep the throttle plate moving toward the
minimum position. (Negative)
Units: V
Detail: Indicates the decremental drive voltage to the throttle motor to keep the throttle plate moving toward minimum
position. This decremental value is applied as necessary after the throttle plate stops moving due to the u Pos Cal
Negative Init voltage. This parameter should be a negative value.
uPsnCalInc_Thresh_ChX
Tip Strip: Threshold for incremental throttle motor positive voltage after the throttle plate stops moving. (Positive)
Units: V
Detail: Indicates a threshold for incremental throttle motor positive voltage after the throttle plate stops moving.
When this incremental threshold is reached, the drive stops and transitions to the negative calibration phase. This
parameter should be a positive value.
uPsnCalDec_Thresh_ChX
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...