NI EDIDS-2400 Series User Manual | © National Instruments | 183
Detail: Set to
FAULT
upon the detection of a pattern-specific crank feature while the
reached the expected value.
Encoder Patterns:
Indicates
FAULT
when an EncZ rising edge occurs before the expected number of Crank teeth
have been counted.
N-M Patterns:
Indicates
FAULT
when a gap occurs before the expected number of Crank teeth have been counted.
N+1 Patterns:
Indicates
FAULT
when a Plus1 tooth occurs before the expected number of Crank teeth have been
counted.
The FAULT condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by pressing the
button.
MissedGapFlag
Tip Strip: Indicates that the crank gap was not detected when expected
Detail: This indicator only applies to
. Indicates
FAULT
when an excess number of crank teeth are
counted before the gap is detected. In other words, physical teeth are received at the location where a gap is
expected. This condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by pressing the
button.
MissedCamFlag
rising edge was not detected when expected
Detail: This indicator only applies to encoder patterns. Indicates
FAULT
when an excess number of crank teeth are
This condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by pressing the
button.
MissedPlus1Flag
Tip Strip: Indicates that the crank Plus1 pulse was not detected when expected
Detail: This indicator only applies to
FAULT
when an excess number of crank teeth are
counted before the Plus1 tooth is detected. In other words, evenly spaced teeth are received at the location where
a Plus1 tooth is expected. This condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by
pressing the
AutoClearFlagWhileCranking
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...