NI EDIDS-2400 Series User Manual | © National Instruments | 51
3.3.3.2 Port Fuel Injectors to PFI Channels
The DI Driver System supports an optional PFI Driver module. The PFI Driver module has four channels, PFI1 –
PFI4, for driving port fuel injectors. Each PFI driver channel is capable of driving low or high impedance port fuel
injectors.
Driving Low Impedance Injectors
Low impedance injectors will have approximately 2 ohms resistance across the solenoid. The low resistance allows
higher current through the solenoid to enable faster valve opening times. However, the high current is not needed for
the entire duration of the injection event in order to keep the valve open. The initial current level is referred to as the
peak current phase and the current level for the remaining injection duration is referred to as the hold current phase.
Typically, the peak current phase is 4A and the hold current phase is 1A.
Driving High Impedance Injectors
High impedance injectors will have approximately 12 ohms resistance across the solenoid. Typically, less than 1
amp is required to open and hold the solenoid valve. Only one current control phase is required to operate high
impedance injectors at a constant current level.
Refer to the
for detailed information on configuring PFI Driver channels.
Wiring diagram for up to four port fuel injectors to the PFI channels of the PFI Driver module is shown in diagram
3.3.3.2.a. (NI recommends using 18 AWG wire (or larger) for port fuel injectors.)
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...