background image

6417

Quick Start Guide
ENGLISH

CLAMP-ON GROUND TESTER

WITH AEMC

®

 INSTRUMENTS

Summary of Contents for AEMC 6417

Page 1: ...6417 Quick Start Guide ENGLISH CLAMP ON GROUND TESTER WITH AEMC INSTRUMENTS ...

Page 2: ...at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www aemc com Serial Catalog 2141 02 Model 6417 Please f...

Page 3: ...heet 20 languages 1 Quick Start Guide 1 USB Stick with User Manual DataView Software Clamp on Ground Tester Model 6417 Cat 2141 02 Hard Accessory Case Cat 2141 50 5 Ω Calibration Loop Cat 2141 51 Bluetooth Adapter Cat 2126 45 PRODUCT PACKAGING Shipping Contents ...

Page 4: ...understand completely Indicates important information to acknowledge This product has been declared recyclable after analysis of its life cycle in accordance with the ISO14040 standard This product complies with the Low Voltage Electromagnetic Compatibility European directives 73 23 CEE 89 336 CEE This product complies with the requirements that apply in the United Kingdom specifically regarding L...

Page 5: ...fications for voltage or category Do not use the instrument if it appears damaged incomplete or poorly closed Before each use check the condition of the housing s insulation If the insulation is deteriorated even partially on any item it must be set aside for repair or scrapping Use personal protection equipment when appropriate When handling the instrument keep your fingers behind the physical gu...

Page 6: ... 8 Rotary Switch Selects the measurement functions and instrument SET UP 9 HOLD Freezes the last measured value on the display Turns the Bluetooth ON OFF when the switch is set to MR or SET UP Rotary Switch Functions Range Description OFF Instrument is powered OFF Ω A Simultaneous selection of the Loop Impedance measurement and the Leakage Current measurement A Current measurement MR Memory Recall...

Page 7: ...udible alarms When the rotary switch is set to SET UP Validates when browsing in the menus and values When the rotary switch is set to MR Advanced Mode Switches the display through the measurement screens and the measurement date time HOLD AUTO HOLD When the rotary switch is set to Ω A Freezes the measurement display for while the HOLD button is pressed The NOISE clamp open and alarm overshoot ico...

Page 8: ...ode 12 Displays the version number 13 Not used Selecting a Specific Menu Use the following buttons to select a specific menu item Button Action Moves up in the menu tree Moves down in the menu tree Selects the menu displayed or return to the previous menu Refer to 4 4 in the user manual for complete details on SET UP menu items Inserting the Batteries 1 Disconnect the instrument from any connectio...

Page 9: ...power Setting the clock allows time stamping of the measurements 1 Set the function switch to Ω A All icons on the display will light up for approximately two seconds 2 Enter the date and time of the device using the and buttons The date and time can also be configured before a measurement in SET UP Standard and Advanced Modes The Ground Resistance Tester has two modes Standard Mode Makes the stan...

Page 10: ...factory specifications we recommend that it be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promp...

Page 11: ...n our website at www aemc com warranty html Please print the online Warranty Coverage Information for your records What AEMC Instruments will do If a malfunction occurs within the warranty period you may return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will repair or replace the faulty material at our dis...

Page 12: ...AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 06 22 99 MAN 100396 v6 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved ...