1.1 Outline
1-13
The teminal block type number (and its pin layout) differs from each other depending on the shipping date.
(1) In case of PM5DW-50V4 (Manufacture: Yoshida Electric)
(FD controller)
46
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
11
13
5
21
7
23
15
9
17
3
25
27
0
42
29 31
19
33
35
37
39
41
40
43
45
47 49
1
48
44
Table 1-5 Terminal block TBX-1 pin layout
Pin No.
Marking
I/O
Signal name
Pin No.
Marking
I/O
Signal name
0 IN5A+
SI
External emergency stop 1+
1 IN5A-
SI
External emergency stop 1-
2 IN5B+
SI
External emergency stop 2+
3 IN5B-
SI
External emergency stop 2-
4
IN6A+
SI
Safety plug 1+
5
IN6A-
SI
Safety plug 1-
6
IN6B+
SI
Safety plug 2+
7
IN6B-
SI
Safety plug 2-
8
IN7A+
SI
Protective stop 1+
9
IN7A-
SI
Protective stop 1-
10
IN7B+
SI
Protective stop 2+
11
IN7B-
SI
Protective stop 2-
12 IN8A+
SI External enable SW 1+
13 IN8A-
SI
External enable SW 1-
14 IN8B+
SI External enable SW 2+
15 IN8B-
SI
External enable SW 2-
16 IN9A+
SI General safety input 11+ 17
IN9A- SI
General safety input 11
18 IN9B+
SI General safety input 12+ 19
IN9B- SI
General safety input 12-
20 IN10A+
SI General safety input 21+ 21
IN10A- SI
General safety input 21-
22 IN10B+
SI General safety input 22+ 23
IN10B- SI
General safety input 22-
24 IN11A+
SI General safety input 31+ 25
IN11A- SI
General safety input 31-
26 IN11B+
SI General safety input 32+ 27
IN11B- SI
General safety input 32-
28 IN12A+
SI General safety input 41+ 29
IN12A- SI
General safety input 41-
30 IN12B+
SI General safety input 42+ 31
IN12B- SI
General safety input 42-
32 IN13A+
SI General safety input 51+ 33
IN13A- SI
General safety input 51-
34 IN13B+
SI General safety input 52+ 35
IN13B- SI
General safety input 52-
36 GPIN13
I Tool
number
1
37 GPIN14 I Tool
number
2
38 GPIN15
I Tool
number
3
39 GPIN16 I Tool
number
4
40 P1
P 24V
41 P1
P
24V
42 INCOM
I Tool No. input COM 43
M1
G
24V
system
GND
44
SO
Ext.l EMG stop out 1+
45 EX_EMG1-
SO
Ext.l EMG stop out 1-
46
SO
Ext.l EMG stop out 2+
47 EX_EMG2-
SO
Ext.l EMG stop out 2-
48
X24V
P
Ext. DC24V power
49
X0V
P
Ext. DC24V GND
SI:Safety Input, I:Monitor input, SO:Safety output, P:Power, G:Ground
129mm
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......