7.2Troubleshooting
7-14
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
1-2 -
This error occurs if a failure
happens in the diagnostic
circuit of the output signal.
Internal error
Diagnostic
circuit
E1106
E28
28
3 -
This error occurs if a failure
happens in the diagnostic
circuit of the power source
voltage.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
Monitor output
E1106
E29
29 - -
This error occurs if the
monitor output signal is not
outputted normally.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
Parameter
memory
E1106
E30-32
30-32 - -
This error occurs if the
storage memory for the
parameters does not work
normally.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
Serial
communication
E1106
E33-35
33-35 - -
This error occurs if the serial
communication in the RMU
does not work normally.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
ADC
E1106
E36
36 - -
This error occurs if the AD
converter for the power
source voltage monitoring
does not work normally.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
USB
E1106
E37
37 - -
This error occurs if the USB
communication with the main
CPU does not work normally.
Turn OFF and ON the
controller power.
Replace the RMU.
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......