7.2Troubleshooting
7-20
[Troubleshooting for the "Robot emergency stop input signal inconsistency"]
Press [R] key of the teach
pendant twice to reset the
error
Press the emergency stop button of the Teach
pendant or the operation panel and then press
[R] key 2 times to reset the error.
Press the emergency stop button of the operation panel or the teach
pendant and then check the LED PD4,PD5 of UM367
Was the error released?
Replace the I/O board
(UM367-10)
Was the error released?
NO
NO
Does the ON/OFF condition match?
YES
Was the error released?
Replace the Teach pendant or
the operation panel.
NO
Was the error released?
Replace the RMU and make the
setting, check, and approvement.
NO
Was the error released?
The internal wiring of the controller may be
wrong. Please contact our service center.
NO
Complete
YES
YES
NO
YES
YES
YES