5.3Settings for the safety PLC
5-7
11
Press the button of "Close" in the screen of "Select Module Type"
>>The added module will be displayed in the "Controller Organizer".
12
Make a connection with the Safety PLC. Select "Who Active" from the "Communications"
menu.
>>The following screen will be displayed. Select the PLC and press "Go Online".
POINT
If a message like "The project of the RSLogix500 and the Safety PLC does not
match" is displayed, please download the project to the Safety PLC.
13
Make the setting of the SNN (Safety Network Number). Right-click the added
"ETHERNET-SAFETYMODULE <Name>" and select the "Properties".