3.2Operation procedure
3-5
3.2.3
Range setting
The range setting is the function of making setting of the safety fence and the part range as well
as the “Robot wrist / tool / workpiece / arm” movement limit areas.
If the robot wrist, tool, workpiece, arm, reaches the limit range, an error will occur.
This section defines the limit lines to specify the safety fence area and the part range.
The limit line settings are made by entering X-Y coordinate values at two points.
1
Open <Constant Setting> - [3 Machine constants] - [33 Virtual Safety Fence] [1
Range setting] menu.
>> A screen like shown below will appear.
Part range
Safety
fence
Safety
fence
Safety fence
Safety fence
Part range
Part range