7.2Troubleshooting
7-15
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
Internal memory
E1106
E38
38 - -
This error occurs if a failure
happens in the diagnostic for
the internal memory of the
RMU.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
Program
memory
E1106
E39
39 - -
This error occurs if a failure
happens in the diagnostic for
the program memory of the
RMU.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Internal error
CPU
E1106
E40
40 - -
This error occurs if a failure
happens in the diagnostic for
the CPU of the RMU.
Turn OFF and ON the
controller power.
Replace the RMU.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB2
SUB3
Description of trouble
Remedy
Communication
stop
E1108
-
- - -
This error occurs if the
communication between the
CPU board and the RMU
has stopped.
Check the connector
CNCOM of the RMU.
Check if the power is
supplied to the RMU.
Replace the RMU.
Connection error E1113
-
-
- -
This error occurs if the RMU
is not connected correctly.
Check the connection of
the RMU by "Servo
amplifier unit" menu.
Check the communication
line to the RMU.
Check the voltage of the
power source of the RMU
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......