4.3Confirmation of parameters
4-18
Table 4-10 Mechanism parameters
Parameter
Function
TCP stop watch limit
TCP position abnormal deviation (mm) when stop monitoring is input
TCP speed level (H)
1-4
TCP abnormal speed (mm/sec) in high speed
Distance of tool watch TCP position abnormal deviation (mm) when verifying the tool
Arm length
One of the mechanism parameter to define the arm length
Setting angle
One of the mechanism parameter to define the arm angle
Offset length
One of the mechanism parameter to define the arm length
Offset angle
One of the mechanism parameter to define the arm angle
Machine type 1
Parameter to classify the mechanism type
Wrist type
Parameter to classify the wrist type
Total axes
Quantity of axis of the mechanism
Installed angle
Parameter to define the angle that mechanism is installed
Amp No.
Amplifier number to which the mechanism is connected
Start axis
Starting axis number in amplifier to which the mechanism is connected
Parent Mech
Parent mechanism number to which the mechanism is connected
Tool weight
Parameter to define the tool weight
Control type
Mode parameter of the RMU
Amp setting
Amp assignment
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......