'15 • HM-T-246
N o display
N o display
It can operate but no hot water comes out ()
Stay
OFF
. Applicable Model
. Troubleshooting
All models
Diagnosis
Countermeasure
Is enough
supply water pressure
secured?
Is the
water pressure 0.1Mpa
or higher?
Is the
usage of hot water
amount too much?
(25liter/min or
more?)
Are
there any points to be
reviewed?
Check whether hot water comes out
Check availability to operate heat pump water heater
and the operating condition of heat pump water heater
Check the hot water amount in the cylinder
Check water pressure and water volume
of the water circuit
Check and rectify
the water circuit
࣭
Check water circuit
࣭
Check and rectify the pressure loss
and leak and etc
YES
YES
YES
NO
NO
YES
NO
NO
Check and secure the
supply water pressure
・
Check the pressure loss
in the water circuit and
secure enough water
pressure.
・
Check height difference
and piping length
・
Size up the piping
It is normal
Check water circuit
Strainer (If it is clogged,
clean it up)
Opening of valves
Mixing valve
By-pass circuit
Leak
Usage of hot water amount
is too much
. E rror detection method
. Condition of error displayed
. P resumable cause
・
Insufficient supply water
pressure
・
Too much pressure loss of
water circuit
N ote:
Error code
Remote control:
7-segment display:
LED
Green
Red
Heat pump
water heater
Keep
flashing
Content
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Summary of Contents for ESA30E-25
Page 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...