'15 • HM-T-246
4.8 7-segment display and compressor stop factor
(1) 7-segment code (P) list
Following list shows the codes used for the setting of option functions and for the adjustment of parameters at site.
For the methods to change settings, refer to the -segment setting procedure on the page 0.
Code N o.
Data display
Data display range
Minimum unit
Remarks
<Setting by service personnel>
P 0
0: (Factory default)
0
‐
−
0: Anti-snow outdoor fan control invalid (Factory default)
: Anti-snow outdoor fan control setting valid
: Anti-snow outdoor fan control setting valid
: Anti-snow outdoor fan control setting valid
P
time setting
0: (Factory default)
0, 0 ~ 00 (sec)
0
P
Demand rate change value
OFF: (N ormally)
000
、
00
、
00
、
00
−
Setting value for -step demand input
Ordinary demands are set with DIP SW.
P
DCV
0: (Factory default)
0
‐
0
0: Operation output
: E rror output
: Compressor ON output
: Fan ON output
: Water shortage output
: Water pump ON output
: Anti-freezing circuit output
: Defrost operation output
: Hot water storage operation output
: Heat retaining operation output
0: Anti-freezing operation output
: Anti-freezing heater output
: Backup operation output
: Remote control ON
~0: Spare
P
DCV
: (Factory default)
0
‐
0
P
CN S function assignment
0: (Factory default)
0
‐
0
0: Stop input (Master)
: Demand input (Master)
: Fan anti-snow control input (Master/Slave independent)
: Operation input (Operation/N ormal) (Master)
: P ause input (P ause/N ormal) (Master)
: -step demand input (Master)
: AF error (Remote control display only)
(Master/Slave independent)
: AF error (E rror display)
(Master/Slave independent)
~ 0: Spare
P
CN S function assignment
: (Factory default)
0
‐
0
P
CN S function assignment
: (Factory default)
0
‐
0
P
CN G function assignment
: (Factory default)
0
‐
0
P
CN G function assignment
: (Factory default)
0
‐
0
P 0
Initial setting operation status
0: (Factory default)
0
‐
: Interruption
: Completed
P
CWFV aperture correction value
0: (Factory default)
-0
‐
+ 0
Range of auto correction by the primary setting operation
is from - to + .
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Summary of Contents for ESA30E-25
Page 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...