0
-
'15 • HM-T-246
4.7. Method of draining water from gas cooler
If the heat pump water heater is left without power source in winter, water in the gas cooler may freeze, damaging the heat
deemergesed for long time.
(1) Products produced before November 2013
1) Close the valves at the hot water supply and the water supply pipe sides.
2) Remove the service panels both at the front and the rear.
Following instructions are based on a test unit equipped with the water piping only, to show better the relative positions of
pipes and drain valves.
Intercooler
Air bleed valve
Flow regulating valve
CWFV1
Gas cooler
Hot water outlet
Drain outlet
Supply water inlet
Water pump
Drain valve
Rear view
Heat pump water heater
Arrows indicate water flow directions.
Configuration of water pipes