'15 • HM-T-246
Error code
Remote control:
7-segment display:
LED
Green
Red
Heat pump
water heater
Keep
flashing
Content
N o display
N o display
Anomalous sound and vibration ()
Stay
OFF
. Applicable Model
. Troubleshooting
All models
Diagnosis
Countermeasure
Is the
anomalous sound heard
during operation or just
after stopping operation
of heat pump water heater?
NO
NO
Does the
anomalous sound come
not only from heat pump
water heater but also from the
whole building?
Is it a sound from outdoor fan?
YES
YES
Is the
hot water storage
operation
going well?
Is it
a sound generated
by touching the fan
with something?
Does the
anomalous sound continue
for long period of time?
YES
NO
NO
NO
Hushing sound is
heard within
30 minutes
YES
YES
NO
YES
Go to previous page
Heat pump water heater is not a cause.
If option parts is used , check the
secure connection them.
If the heat pump water heater is dirty
on the heat exchanger, clean it up.
Since the outdoor fan is controlled
of rotation speed and beat note are not
abnormal.
If it is unendurable sound for the
customer, please ask our distributor.
If some foreign matter like icicle is
biting, remove it.
In case of the installation in cold region
installation of snow prevention hood
on the heat pump water heater is
recommendable.
Make a diagnosis according the
" N o hot water comes out"
Under the low outdoor air temperature
condition, defrost operation is done in
order to melt down the frost on the heat
exchanger.
During defrost operation, hushing
sound can be heard, but it is not
abnormal.
And under the transitional operating
condition like starting or stopping,
heard, but it is also not abnormal.
of refrigerant may sometimes be heard,
because the refrigerant is charged in the
heat pump water heater.
In case of the installation in a quiet place,
the low frequency sound may be heard from
the heat pump water heater during the hot
If it is unendurable for the customer, please
elect sound insulation wall or change
installation location of the heat pump water
heater
. E rror detection method
. Condition of error displayed
. P resumable cause
N ote:
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Summary of Contents for ESA30E-25
Page 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Page 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...