ii
Periodically check the unit base for dam-
age.
If the damage is left uncorrected, the unit will fall and
cause serious injury.
Consult your dealer for the proper disposal
of the unit.
The refrigerant oil and the refrigerant in the unit will
pose a risk of environmental pollution, fire, or explo-
sion.
Do not use means to accelerate the defrost-
ing process or to clean, other than those
recommended by the manufacturer.
The unit shall be stored in a room without
continuously operating ignition sources
(for example: open flames, an operating gas
appliance or an operating electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain
an odour.
Install, operate, and store the unit in a space
with as much floor area as indicated in the
figure at right, and be sure to take safety
measures.
The Hydro unit shall not be installed in a
condition with certain floor area and the re-
frigerant amount as shown in the figure be-
low.
The unit shall be properly stored to prevent
mechanical damage.
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
350
400
450
500
550
600
650
At least two safety
measures are required.
Room volume [m
3
]
System refrigerant amount [kg]
NG (ISO 5149)
At least one safety
measure is required.
Construction guidance
Children should be supervised to ensure
that they do not play with the appliance.
Do not operate the unit with the panels and
guards removed.
Rotating, hot, or high-voltage parts may cause injury,
electric shock, or fire.
Do not touch fans, heat exchanger fins, or
the sharp edges of components with bare
hands.
Doing so may result in injury.
Wear protective gloves when working on
the unit.
Failure to do so may result in injury.
High-pressure pipes poses a risk of burns if touched
with bare hands while the unit is in operation.
Check that markings of the unit are not illeg-
ible.
Illegible warning or caution markings may cause dam-
age to the unit, resulting in injury.
If the ambient temperature can drop below
freezing while the heat-source unit is not in
use, blow the water out of the pipes or fill
them with anti-freeze solution.
Failure to do so may cause the water in the pipes to
freeze and damage the unit.
Water from burst pipes may result in water-damage to
the furnishings.
Make sure the supply-water flow rate falls
within the specified range.
Failure to maintain the adequate flow rate can result in
corrosion of the heat-source unit.
Water from corroded pipes can result in water-damage
to the furnishings.
0000002721.BOOK ii ページ 2019年4月1日 月曜日 午前9時30分
Summary of Contents for City Multi CMH-WM250V-A
Page 1: ......
Page 11: ...GB_BS_01_G 0000005109 BOOK 2 ページ 2019年5月9日 木曜日 午前10時1分 ...
Page 37: ...GB_BS_02_E 0000004972 BOOK 2 ページ 2019年5月8日 水曜日 午後2時48分 ...
Page 67: ...GB_BS_03_E 0000004974 BOOK 2 ページ 2019年5月9日 木曜日 午後6時11分 ...
Page 91: ...GB_BS_04_E 0000004976 BOOK 2 ページ 2019年5月8日 水曜日 午後2時57分 ...
Page 119: ...GB_BS_05_E 0000004980 BOOK 2 ページ 2019年5月9日 木曜日 午後6時18分 ...
Page 149: ...GB_BS_06_E 0000004982 BOOK 2 ページ 2019年5月8日 水曜日 午後3時4分 ...
Page 163: ...GB_BS_07_E 0000004984 BOOK 4 ページ 2019年5月17日 金曜日 午前8時21分 ...
Page 391: ...GB_BS_09_C 0000005077 BOOK 2 ページ 2019年5月8日 水曜日 午後3時12分 ...
Page 409: ...GB_BS_10_E 0000004988 BOOK 2 ページ 2019年5月9日 木曜日 午前8時15分 ...
Page 436: ......