"Neutral measurement" application
:
The initialization data block contains the reference quantity and the reference weight. The
results block contains the gross, net and tare weights and, as a result, the item quantity.
–------------------
nRef 2 o
wRef + 1.200 kg
G# + 14.700 kg
T + 0.300 kg
N + 14.400 kg
Qnt 12 o
–------------------
"Percentage weighing" application:
The initialization data contains the reference percentage and the reference weight. The
result data contains the gross, net and tare weights and, as a result, the percentage value,
displayed either as a residual value or as a loss value.
Residual display
–------------------
nRef 100 %
wRef + 2.100 kg
G# + 1.859 kg
T + 0.200 kg
N + 1.659 kg
Prc 79 %
–------------------
Loss display
–------------------
nRef 100 %
Wxx% + 2.100 kg
G# + 0.641 kg
T + 0.200 kg
N + 0.441 kg
D 21 %
–------------------
"Checkweigher" application:
The initialization data contains the target weight, the min. weight and the max. weight.
The results data always contains the gross, net and tare weights. The additional results
can be output in 2 diferent display types:
-
Weight display: In the good and poor range, the deviation from the target weight is
always printed as a percentage and an absolute deviation.
-
Limit value display: In the good range, the deviation from the target weight is printed
as a percentage and an absolute deviation.
Combics 2 Series Complete Scales Models CAW2P, CAW2S
8 Data interfaces
EN-186