Chapter 12: Meridian 1 configuration for Meridian Link/CCR
305
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Configure ESDI or MSDL port (X11 Release 18 or later)
The IPE Module or the Application Module is connected to the Meridian 1
through a port on a QPC513 ESDI card (vintage G or later), NTAK02
SDI/DCH card (Option 11, IPE Module only), or NT6D80 MSDL card.
The port must have the Application Module Link (AML) identified
(VSID 0Ð15). Define the port and its characteristics by responding to the
following prompts in LD 17.
Option 11 ESDI configuration
Table 108
LD 17ÑConfigure ESDI port (Option 11)
Prompt
Response
Comment
REQ
CHG
Create or change information in the
database
TYPE
CFN
Configuration record data block
ADAN
NEW AML x
Add AML on port x (VASID 0Ð15)
CDNO
0Ð15
Serial Data Interface Card Number
PORT
0Ð3
Port number on SDI/DCH card
DES
LINK/CCR
AML port designation (such as
ÒMeridian LinkÓ)
BPS
19200
19,200 bps baud rate (19.2 kbps). The
AML (connection from SDI/DCH card
to the IPE Module) rate must match
the baud rate of link 0 on the IPE
Module.
CLOK
INT
Internal clock (this prompt only
appears for ESDI)
IADR
3
Individual address for the data-link
level-HDLC protocol
RADR
1
Remote address for the data-link level
HDLC protocol
ÐcontinuedÐ
Summary of Contents for Link/Customer Controlled Routing
Page 2: ...ii 553 3202 210 Standard October 1998...
Page 4: ...iv Publication history 553 3202 210 Standard October 1998...
Page 14: ...xiv Contents 553 3202 210 Standard October 1998...
Page 56: ...38 Chapter 3 Overview of Customer Controlled Routing 553 3202 210 Standard October 1998...
Page 132: ......
Page 168: ...150 Chapter 8 Hardware installation procedures 553 3202 210 Standard October 1998...
Page 388: ...370 Chapter 13 Meridian Mail configuration 553 3202 210 Standard October 1998...
Page 562: ...544 Chapter 19 Single Terminal Access 553 3202 210 Standard October 1998...
Page 570: ...552 Chapter 20 Ordering 553 3202 210 Standard October 1998...