130
Chapter 8: Hardware installation procedures
553-3202-210 Standard October 1998
If your Application Module does not have CCR activated, the
MVME332XT(S) card may not be present. If so, skip steps 1Ð3 and begin at
step 4.
1
Remove the screws at the top and bottom of the MVME332XT(S)
card faceplate.
2
Pull the MVME332XT(S) card out of the Application Module.
Check the switches as indicated in Tables 29 and 30.
Table 29
MVME332XT ACC card switch settings
Switch
Position
1
2
3
4
5
6
7
8
S1
on
off
off
off
off
on
on
on
S2
off
off
on
on
Table 30
MVME332XT ACC card jumper settings
Block
Jumper setting
J1
1Ð2, 5Ð6, 7Ð9, 8Ð10, 11Ð12, 15Ð17
J4
1Ð2
3
Replace the MVME332XT(S) card and replace the screws at the top
and bottom of the faceplate.
4
Remove the screws at the top and bottom of the MVME333-2 XCC
card faceplate.
5
Pull the MVME333-2 XCC card out of the Application Module.
Check the switches as indicated in Table 31 and Figure 34.
Summary of Contents for Link/Customer Controlled Routing
Page 2: ...ii 553 3202 210 Standard October 1998...
Page 4: ...iv Publication history 553 3202 210 Standard October 1998...
Page 14: ...xiv Contents 553 3202 210 Standard October 1998...
Page 56: ...38 Chapter 3 Overview of Customer Controlled Routing 553 3202 210 Standard October 1998...
Page 132: ......
Page 168: ...150 Chapter 8 Hardware installation procedures 553 3202 210 Standard October 1998...
Page 388: ...370 Chapter 13 Meridian Mail configuration 553 3202 210 Standard October 1998...
Page 562: ...544 Chapter 19 Single Terminal Access 553 3202 210 Standard October 1998...
Page 570: ...552 Chapter 20 Ordering 553 3202 210 Standard October 1998...