Chapter 11: Peripheral device cabling interface
287
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
4
Connect the modem directly to the IPE Module or Application
Module, as described in Chapter 9, ÒMeridian Link/CCR interface
cabling.Ó
If the modem installation is successful, the LED labelled ÒTRÓ on the
front panel of the modem lights up.
The following procedure explains how to configure the UDS 2440 modem
using a workstation.
1
Connect the modem to a workstation and apply power to both.
2
Enter each entry shown under the ÒInputÓ column in Table 104 and
press [Enter]. The system response to each entry should be ÒOK.Ó
Table 104
UDS 2440 modem configuration (workstation)
Input
System response
atz
OK
at&f
OK
ats0=1
OK
at&d3
OK
at&s1
OK
at&c1
OK
at&w
OK
3
Power down the workstation and the modem.
4
Disconnect the modem from the workstation.
5
Connect the modem to the IPE Module using an NT1R03HF cable,
or to an Application Module using an NT7D99AA cable.
If the modem installation is successful, the LED labelled ÒTRÓ on the
front panel of the modem lights up.
Summary of Contents for Link/Customer Controlled Routing
Page 2: ...ii 553 3202 210 Standard October 1998...
Page 4: ...iv Publication history 553 3202 210 Standard October 1998...
Page 14: ...xiv Contents 553 3202 210 Standard October 1998...
Page 56: ...38 Chapter 3 Overview of Customer Controlled Routing 553 3202 210 Standard October 1998...
Page 132: ......
Page 168: ...150 Chapter 8 Hardware installation procedures 553 3202 210 Standard October 1998...
Page 388: ...370 Chapter 13 Meridian Mail configuration 553 3202 210 Standard October 1998...
Page 562: ...544 Chapter 19 Single Terminal Access 553 3202 210 Standard October 1998...
Page 570: ...552 Chapter 20 Ordering 553 3202 210 Standard October 1998...