142
Chapter 8: Hardware installation procedures
553-3202-210 Standard October 1998
Installing an NTAK02 SDI/DCH card
On an Option 11 system, if there is no port available on the CPU/Conf or
TDS/DTR cards, you can obtain additional SDI or ESDI ports by installing
an NTAK02 SDI/DCH card before the IPE Module is configured.
This card provides the communication connection for the AML link from
the Option 11 to the IPE Module. The Option 11 port used for the AML link
connection must be configured for DCE and RS-232, and the switches set
for ESDI.
This card also provides a connection for the conshare feature. The port used
for conshare must be configured for DCE and the switches set for SDI.
1
Unpack and inspect the card.
2
Set the switches as shown in Table 37. Set the jumpers as shown in
Table 38.
3
Insert the card into a common equipment slot and lock it into position.
Table 37
NTAK02 SDI/DCH card switch settings
Switch 1-1
Switch 1-2
Port 0
Port 1
Off
Off
SDI
DCH
Off
On
SDI
DPNSS
On
On
Ñ
ESDI
Switch 1-3
Switch 1-4
Port 2
Port 3
Off
Off
SDI
DCH
Off
On
SDI
DPNSS
On
On
Ñ
ESDI
Note:
For AML link, port must be set for ESDI.
Note:
SDI ports are 0 and 2. ESDI ports are 1 and 3.
Summary of Contents for Link/Customer Controlled Routing
Page 2: ...ii 553 3202 210 Standard October 1998...
Page 4: ...iv Publication history 553 3202 210 Standard October 1998...
Page 14: ...xiv Contents 553 3202 210 Standard October 1998...
Page 56: ...38 Chapter 3 Overview of Customer Controlled Routing 553 3202 210 Standard October 1998...
Page 132: ......
Page 168: ...150 Chapter 8 Hardware installation procedures 553 3202 210 Standard October 1998...
Page 388: ...370 Chapter 13 Meridian Mail configuration 553 3202 210 Standard October 1998...
Page 562: ...544 Chapter 19 Single Terminal Access 553 3202 210 Standard October 1998...
Page 570: ...552 Chapter 20 Ordering 553 3202 210 Standard October 1998...