Lingenfelter NCC-001 Nitrous Control Center Installation and Operating Instructions
81
Access from the Computer Program:
From the
, select the stage by pressing either the "Nitrous1" button or the "Nitrous2" button. The
"Pulse Frequency" setting is found in the "Stage Solenoid Pulse Freuency" dialog box under the "Options" Tab.
Click on one of the settings in the scroll-down menu to select the desired pulse frequency setting.
See
Appendix B: Nitrous & Fuel Operation
6.11
Resume Start Percentage
This setting determines the percent at which the Nitrous resumes if the user has to lift the throttle after the nitrous
system is active. This setting is only valid if the Hold And Wait option is ON. This setting is used with the Resume
Percent Per Pulse setting to build a Resume Ramp. If the Resume Start Percent is greater than the current
Nitrous percent, the Resume Ramp is ignored.
Valid Range is 10% to 100% in 1% increments. A setting of 100% disables this feature (no ramp / instant ON).
Access from the Controller:
From the
, select the stage by pressing either the "N2O-1" button or the "N2O-2" button. Press the
“DOWN” arrow button repeatedly until the "Resume Start Percent" menu selection is highlighted and then press
the “ENTER” button. Using the “LEFT” and ”RIGHT” arrow buttons adjust the setting. Press the “SAVE” button to
accept the new setting or press the “ESC” button to exit with no change.
Access from the Computer Program:
From the
, select the stage by pressing either the "Nitrous1" button or the "Nitrous2" button. The
"Nitrous Resume %" setting is found in the "Nitrous Resume Ramp" dialog box under the "Options" Tab. Click
the "UP" and "DOWN" arrow buttons or type in any numeric value in the valid ranges shown above.
See
Summary of Contents for NCC-001
Page 5: ...Introduction Part I...
Page 11: ...Parts List Part II...
Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...
Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...
Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...
Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...
Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...
Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...
Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...
Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...
Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...
Page 55: ...Getting to Know the User Interface Part IV...
Page 59: ...Global Menu Setup Options Part V...
Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...
Page 85: ...Setup Menu Part VII...
Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...
Page 161: ...Appendices Part IX...