Access from the Computer Program:
From the
, press the "Timer" button. The "Output RPM Off" option is found in the "RPM Based
Setup" dialog box under the "Options" Tab. Click the "UP" and "DOWN" arrow buttons or type in any numeric
value in the valid ranges shown above.
RPM Hysteresis Percentage
This setting controls the percentage of hysteresis for the engine RPM if the timer is setup as a RPM window
switch controlled output. The hysteresis percentage is based off of the full scale range (16000 RPM). For
example, you set the RPM On to 4000 and the RPM Off to 8000. The following chart shows the effect of a 1%
hysteresis on those values (1% of 16000 = 160 RPM):
Hysteresis
RPM On Setting = 4000
RPM Off setting = 8000
0%
ON at 4000 RPM
OFF at 4000 RPM
OFF at 8000 RPM
ON at 8000 RPM
1%
ON at 4000 RPM
OFF at 3840 RPM
OFF at 8000 RPM
ON at 7840 RPM
In the above example with a 0% hysteresis, as the engine RPM rises above 4000 RPM, the Timer Output is turned
on. Then, when engine speed exceeds 8000 RPM, the Timer Output is turned off. As the engine RPM drops, the
Timer Output is turned on when the engine speed drops below 8000 RPM and is then turned off when the engine
speed drops below 4000 RPM. With a 1% hysteresis, the values would be the same when the engine speed is
increasing, but as the engine RPM drops, the Timer Output is turned on when the engine speed drops below 7840
RPM and is turned off when the engine speed drops below 3840 RPM.
For more information on hysteresis values, refer to
The valid range is 0.0-5.0 in 0.1% increments.
Access from the Controller:
From the Main screen press the “SETUP” button and then press the “ENTER” button. Press the "DOWN" button
continuously until the "Timer Setup Menu" is selected, then press "ENTER". Press the "DOWN" button
continuously until the "RPM Hysteresis%" setting is highlighted, then press "ENTER". Using the “LEFT” and
”RIGHT” arrow buttons, adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC”
button to exit with no change.
Access from the Computer Program:
Summary of Contents for NCC-001
Page 5: ...Introduction Part I...
Page 11: ...Parts List Part II...
Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...
Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...
Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...
Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...
Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...
Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...
Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...
Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...
Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...
Page 55: ...Getting to Know the User Interface Part IV...
Page 59: ...Global Menu Setup Options Part V...
Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...
Page 85: ...Setup Menu Part VII...
Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...
Page 161: ...Appendices Part IX...