Lingenfelter NCC-001 Nitrous Control Center Installation and Operating Instructions
63
See
Appendix B: Nitrous & Fuel Operation
5.6
Set Input Polarity
The Input Polarity for the Arming, Clutch, and Shift inputs may be configured for either ground or +12V Arming.
This allows the controller to be configured to work with existing wiring or to eliminate the need for relays to change
the Arming polarity. The current input polarity state is displayed and will be updated when changed. This setting
is global, so it will remain the same regardless of which program you are currently using.
Access from the Controller:
From the
, press the “GLOBAL” button. Press the “DOWN” arrow button repeatedly until the "Set
Input Polarity" menu selection is highlighted and then press the “ENTER” button. Using the “LEFT” and ”RIGHT”
arrow buttons adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC” button to
exit with no change.
Access from the Computer Program:
From the
, press the "SETUP" button. The "Input Polarity" settings is found in the "Input Polarity"
dialog box under the "Options" Tab. Click either the "Ground" or "+12 Volt" button to select the input polarity of
each input.
5.7
Pulses Per Degrees
This setting determines the number of tachometer pulses per revolution of the crankshaft. The following list shows
the available settings for this input. Refer to
Appendix C: Tables and Diagrams
for a table of recommended RPM
pulse counts for different applications.
1 pulse per 720 degrees (or 0.5 pulse per 360 degrees)
1 pulse per 360 degrees
2 pulses per 360 degrees
3 pulses per 360 degrees
Summary of Contents for NCC-001
Page 5: ...Introduction Part I...
Page 11: ...Parts List Part II...
Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...
Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...
Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...
Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...
Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...
Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...
Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...
Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...
Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...
Page 55: ...Getting to Know the User Interface Part IV...
Page 59: ...Global Menu Setup Options Part V...
Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...
Page 85: ...Setup Menu Part VII...
Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...
Page 161: ...Appendices Part IX...