Appendices
162
9.2
Appendix B: Nitrous and Fuel Operation
Progressive Ramp—This adjustability allows the user to tune for rich/lean conditions at different points in the
progressive ramp. Multiple precision timers are included to delay the start of nitrous delivery, advance the fuel
delivery, and to provide an addi12 volt output to control external devices. A resume ramp has been included
so throttle lift transitions and/or gear change transitions can be controlled.
Arming—The system is armed when either a ground or +12V signal is present on the arming terminals. Once
armed and all other activation criteria are met, the Main Timer begins counting down and is displayed on the main
screen. If the Hold & Wait option is ON the system timers will NOT reset if the activation signal is removed (i.e.-
throttle lift). If the Hold & Wait option is OFF the system will reset and start over each time the arming signal is
removed and re-applied.
Nitrous Delay—If this function is set the nitrous timers will NOT begin until this time delay has expired. Each
stage has a separate timer delay setting.
Fuel Advance—After the nitrous delay has timed out this setting is checked. If a fuel advance time has been set
the fuel solenoids will begin operation before the nitrous solenoids. For example if a lean spike was occurring the
system could be programmed to deliver a 80% fuel pulse .050 second before the first nitrous solenoid pulse. It is
recommended to check nozzle flow and total volume flow to insure correct fuel delivery.
Nitrous/Fuel Progressive Ramp—Once armed and the delay and fuel advance timers have expired, the system will
pulse the solenoids as programmed. The nitrous and fuel use independent data to allow greater control. When the
end of the progressive ramp is reached the system will use the last percentage in the progressive ramp until the
main timer expires. When the main timer has expired, the only way to reset the system is to remove the arming
signal.
NOTE:
It is important to note that the data log, once started, will continue to log data until the 25 seconds is
elapsed, even if the Main timer is reset and started again.
Resume Ramp—This setting controls the Percentage that the system returns to after a throttle lift on the next
Solenoid Pulse. Example-the system is at 80% and the throttle is lifted and re-applied, if the Resume Start
Percent was set at 50% the first pulse would be 40%. The Resume Ramp will increase at the rate of the Resume
Percent Per Pulse setting until the system returns to the Percentage it was at before the throttle lift. If the Fuel
and Analog Out settings are at a higher and/or lower setting they are scaled so they resume at the same rate as
the Nitrous Solenoids.
+12 Volt Timer Output—If a setting of 0.000 is entered the Timer Output will turn ON with the First Pulse of the
Nitrous Solenoid. This output can NOT be disabled and the user must remove any wires connected to the Output
terminal to disable any device connected.
Summary of Contents for NCC-001
Page 5: ...Introduction Part I...
Page 11: ...Parts List Part II...
Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...
Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...
Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...
Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...
Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...
Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...
Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...
Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...
Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...
Page 55: ...Getting to Know the User Interface Part IV...
Page 59: ...Global Menu Setup Options Part V...
Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...
Page 85: ...Setup Menu Part VII...
Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...
Page 161: ...Appendices Part IX...