The BMC/IMM/XCC account password (1 of 12 accounts). The default value is
PASSW0RD (with a zero 0 not an O).
Note:
BMC, IMM, or XCC external IP address, account name, and password are all valid for
this command.
Example that does use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
Step 3. Restart the Lenovo XClarity Controller.
Step 4. Restart the server.
Update the DMI/SMBIOS data
The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use the
Lenovo XClarity Provisioning Manager Lite to update the DMI in the UEFI-based server. Lenovo XClarity
Essentials OneCLIcan be used to update the UUID in the UEFI-based server as a command line option.
Lenovo XClarity Essentials OneCLI is an online tool that supports several operating systems; make sure that
you download the version for your operating system.
1. Start the server and press F1 to display the Lenovo XClarity Provisioning Manager Lite system setup
interface.
2. From the System Summary page, click
Update VPD
.
3. Update the asset tag information.
Note:
You can use Lenovo XClarity Essentials OneCLI to update the asset tag for the server.
To download Lenovo XClarity Essentials OneCLI, go to the following site:
https://datacentersupport.lenovo.com/solutions/HT116433
Lenovo XClarity Essentials OneCLI sets the DMI in the Lenovo XClarity Controller. Select one of the following
methods to access the Lenovo XClarity Controller and set the DMI:
• Operate from the target system, such as LAN or keyboard console style (KCS) access
• Remote access to the target system (TCP/IP based)
Step 1. After you haveLenovo XClarity Essentials OneCLI in place, type the following commands to set the
DMI:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
The server machine type and model number. Type
mtm xxxxyyy
, where
xxxx
is the machine
type and
yyy
is the server model number.
<s/n>
The serial number on the server. Type
sn zzzzzzz
, where
zzzzzzz
is the serial number.
<asset_method>
The server asset tag number. Type
asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
.
Hardware replacement procedures
157
Summary of Contents for ThinkAgile VX 4-Socket 4U Certified Node
Page 6: ...iv User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 10: ...viii User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 69: ...Chapter 2 Server components 59 ...
Page 76: ...66 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 96: ...86 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 252: ...242 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 276: ...266 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 284: ...274 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 295: ......
Page 296: ......