Figure 52. Adapter installation (slot 16 to 17)
Step 1. Open the retention latch.
Step 2. Align the adapter with the riser slot and insert it; then, press the adapter into the riser until the
connector is fully seated.
Step 3. Close and lock the retention latch.
If you have no other operations to perform on the riser after installing an adapter in slot 16 to 17:
1. If any of the adapters in the riser have internal cables, make sure that they are connected before
installing the riser in the I/O tray.
2. Install the riser in the I/O tray. See “Install the riser for slot 16 to 17 (riser 3)” on page 222.
3. Install the I/O tray in the chassis and connect all cables. See “Install the I/O tray” on page 154.
System battery (CR2032) replacement
The system battery is in the I/O tray that is accessed from the rear of the server.
Remove the system battery
The system battery is in the I/O tray that is accessed from the rear of the server. After removing the I/O tray
from the chassis, remove the riser for slot 1 to 4 (riser 1) and the adapter in slot 8 to access the battery; then,
remove the battery from the I/O tray.
S002
.
Hardware replacement procedures
105
Summary of Contents for ThinkAgile VX 4-Socket 4U Certified Node
Page 6: ...iv User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 10: ...viii User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 69: ...Chapter 2 Server components 59 ...
Page 76: ...66 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 96: ...86 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 252: ...242 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 276: ...266 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 284: ...274 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Page 295: ......
Page 296: ......