Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0036
User Response
Complete the following steps:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the microprocessor 4 heat sink is securely installed.
5. (Trained service technician only) Make sure that the microprocessor 4 heat sink is installed
correctly and the thermal material is correctly applied.
6. (Trained service technician only) Replace microprocessor 4.
Related links
– Server features and specifications
– Removing a compute book
– Replacing a compute book
– Removing the compute book cover
– Replacing the compute book cover
– Removing a microprocessor and heat sink
– Replacing a microprocessor and heat sink
– Thermal grease
•
806f0108-0a01ffff : [PowerSupplyElementName] has Failed.
IMM has detected a Fault on Power Supply 1.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0086
Appendix C. Integrated management module II (IMM2) error messages
697
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......