SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive
(s).
– Replace the hard disk drive that is indicated by a lit status LED.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
•
806f050d-040bffff : Array [ComputerSystemElementName] is in critical condition.
Drive 11 is part of an RAID array that is in critical condition. Immediate action is required to avoid a system
outage. To identify drives in the critical array all member drives will report this message.
May also be shown as 806f050d040bffff or 0x806f050d040bffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
– Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive
(s).
– Replace the hard disk drive that is indicated by a lit status LED.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
•
806f050d-040cffff : Array [ComputerSystemElementName] is in critical condition.
Drive 12 is part of an RAID array that is in critical condition. Immediate action is required to avoid a system
outage. To identify drives in the critical array all member drives will report this message.
May also be shown as 806f050d040cffff or 0x806f050d040cffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
1104
System x3850 X6 and x3950 X6 Installation and Service Guide
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......